Friday, April 17, 2015

Lutron 9 In 1 Environment Meter SP8001

Lutron 9 In 1 Environment Meter SP8001

This is a very versatile 9 in 1 environment testing meter providing wind speed, light levels, humidity and internal and external (with accessory probe) temperature readings

It's the perfect high quality unit for all your health and safety needs and a variety of other uses.

1. Air velocity
2. Air temperature and humidity
3. Light
4. Air flow
5. Dew point
6. Wet bulb
7. Wind chill
8. Heat index
9. Precision temp (with optional proble)

FEATURES
  • 8mm LCD display with backlight
  • Compact and fully featured
  • Data hold and minimum/maximum readings
  • Lanyard for safe use by idiots who drop things
  • International standards ISO9001 factory calibration certificate

SPECIFICATIONS
  • Powered by CR2032 battery supplied
  • Auto power off 10 minutes (Can be disabled)
  • Dimensions 120H x 45W x 20D mm
  • Weight with battery 160g

ANENOMETER
  • Range 0.4 to 20 m/s 
  • Resolution 0.1 m/s
  • Accuracy < 20 m/s +/- 3% FS
  • Accuracy > 20 m/s +/- 4% FS
  • Units m/s ft/m km/h mph knots

TEMPERATURE
  • Range 0 to 50 deg. C
  • Resolution 0.1 deg. C
  • Accuracy +/- 1.2 deg. C
  • Units degrees C and F

HUMIDITY
  • Range 10 to 95% RH
  • Resolution 0.1% RH
  • Accuracy <70 4="" li="" rh="">
  • Accuracy >70% RH +/- (4% reading + 1.2% RH)
  • Units RH Relative Humidity

LIGHT METER
  • Range 0 to 20,000 Lux
  • Resolution 1 Lux up to 2,200 Lux
  • Resolution 10 Lux over 2,200 Lux
  • Accuracy +/- 5% reading +/- 8 digits
  • Units Lux and Ft-cd (feet candle)

AIR FLOW
  • Range 0.024 to 36000 CMM
  • Resolution 0.001, 0.01, 0.1, 1.0

DEW POINT
  • Range -25.3 to 49.0 deg. C
  • Resolution 0.1 deg. C
  • Units degrees C and F

WET BULB
  • Range -5.4 to 49.0 deg. C
  • Resolution 0.1 deg. C
  • Units degrees C and F

WIND CHILL
  • Range -9.4 to 44.2 deg. C
  • Resolution 0.1 deg. C
  • Accuracy +/- 2 deg. C
  • Units degrees C and F

HEAT INDEX
  • Range -0 to 100 deg. C
  • Resolution 0.1 deg. C
  • Accuracy +/- 2 deg. C
  • Units degrees C and F

PRECISION THERMOMETER (OPTIONAL PROBE)
  • Range -10 to 100 deg. C
  • Resolution 0.1 deg. C
  • Accuracy +/- 1.2 deg. C
  • Units degrees C and F
INDICATIVE LUMINANCE LEVELS
  • 0.00005 lux - Starlight
  • 0.0001 lux - Moonless overcast night sky
  • 0.001 lux - Moonless clear night sky
  • 0.01 lux - Quarter moon
  • 0.25 lux - Full moon on clear night

METER RESPONDS FROM HERE
  • 1 lux - Full moon overhead tropical latitiude
  • 3 lux - Dark limit of civil twighlight with clear sky
  • 50 lux - Family living room
  • 400 lux - Brightly lit office
  • 400 lux - Sunset on clear day
  • 1000 lux - Typical TV studio lighting
  • 32000 lux - Sunlight on average day (min)
  • 100000 lux - Sunlight on average day (max)